The service case comprises a test unit, power supply unit 24 V, connecting cables and adapter cables The test device is suitable for the control and functional testing of proportional servo valves with integrated electronics and an operating voltage of ±15 V or +24 V Simplifies commissioning and troubleshooting in hydraulic systems with servo and proportional valves Service case:
– Dimensions (W x H x D) 450 x 100 x 350 mm
– Weight (empty) 2 kg
– Weight (complete) 4.3 kg
General
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | |
Component series |
1X | 1X/G24 | 1X/G15 | 1X | 1X |
Operating voltage
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | ||||
Operating voltage |
Switch “power selector” |
Switching position “24 V” |
UB |
24 V; –20 % +40 % | |||||
Switching position “±15 V” |
UB |
±15 V; ± 10 % | |||||||
Operating voltage |
U |
90 …264 VAC; 47 … 63 Hz | 115 V / 230 V ± 5 % 50/60 Hz switchable | ||||||
Current consumption of the test device |
I |
0,1 A | |||||||
Current consumption |
Imax |
1.2 A | 29 mA | ||||||
Output voltage |
U |
24 VDC ± 1 V; 3,75 A | +15 VDC ± 0.2 V; 0.25 A –15 VDC ± 0.2 V; 0.25 A |
Inputs
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | ||||
Input connector ES |
Command values at pin E and D |
Ue; Ie |
according to the valve specifications | ||||||
Enable signal at pin C (24 V operation) |
Not active |
UF |
0 … 10 V | ||||||
Active |
UF |
16 V … UB | |||||||
Output socket AB |
Actual value at pin F |
Ue; Ie |
according to the actual value output of the valve | ||||||
BNC socket |
Ue |
0 … ±10 V |
Outputs
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | |||||||
Input connector ES |
Actual value at pin F |
Ua; Ia |
according to the actual value output of the valve | |||||||||
Output socket AB |
Enable signal at pin C (24 V operation) |
Switch “setpoint selector” |
Switching position “internal” or “BNC” |
Enable switch “enable” |
In switching position “off” |
UF |
0 V | |||||
In switching position “on” |
UF |
UB | ||||||||||
Switching position “control” |
In switching position “off” |
UF |
0 V | |||||||||
In switching position “on” |
UF |
according to pin C of the input connector ES | ||||||||||
Command values at pin D and E |
Switching position “internal” or “BNC” |
Pin E |
Reference potential | |||||||||
Pin D |
Ucommand |
0 … ±10 V, if Re valve > 500 Ω | ||||||||||
Icommand |
0 … ±20 mA, if Re valve < 500 Ω | |||||||||||
Switching position “control” |
Pin E and D |
Ucommand |
according to the input connector ES (pin E and D) |
Other information
Type / version |
VT-VET-1 | VT-VETNT-3 | VT-VETNT-2 | VT-VETK-1 | Stecker MS3101A 14S 6P | |||
Fuse |
electronic overload protection | Temperature fuse 130 °C | ||||||
Length of the mains line |
l |
m |
≈ 1.5 | 2 | ||||
Length of the line to the test device |
l |
m |
≈ 1.5 | |||||
Length of the connection cable |
l |
m |
3 | |||||
Connection |
For valve |
Mating connector according to DIN EN 175201-804 | Mating connector VG 95328 | |||||
For test device |
Connector MS3101A 14S 6P | |||||||
Dimensions (W x H x D) |
94 x 54 x 160 mm | 139 x 61 x 36 mm | 86 x 56 x 86 mm | |||||
Weight |
m |
kg |
0.36 | 0.46 | 0.63 | 0.3 |